Re: DPLEX questions [was: Re: Pipes]

New Message Reply Date view Thread view Subject view Author view

Moshe Nissim (moshe++at++orad.co.il)
Fri, 31 Jul 1998 15:16:48 -0700


Thanks for the thorough and quick reply.

> Drops are handled elegantly, it continues to send the current channel
> out if the next one isn't done. At the next retrace, the now completed
> sequential pipe image is sent eventually the right data propagates
> through from the app to the draw processes.

So it's kind of analogous to a double-buffer operation on a single pipe

--
the front buffer continues to be sent until the drawing to the back
buffer is finished?

> > Note, that this frontpanel *replaces* whatever connectors you are > familiar with on an ONYX2 DG board so that 2 or 8 channel analog is not > possible from a single pipe while you have DPLEX installed. You still > have swapready & genlock.


New Message Reply Date view Thread view Subject view Author view

This archive was generated by hypermail 2.0b2 on Mon Aug 10 1998 - 17:57:46 PDT

This message has been cleansed for anti-spam protection. Replace '++at++' in any mail addresses with the '@' symbol.