Re: GL display lists in Performer

New Message Reply Date view Thread view Subject view Author view

Markus Nikolopoulos (mani++at++ppvku.ericsson.se)
Tue, 7 Nov 1995 10:03:33 +0100


> >From: ghock++at++gateway.grumman.com (Greg Hock)
> From: "Angus Dorbie" <dorbie++at++bitch.reading.sgi.com>
>
> Just add it several times bellow pfDCS or pfSCS structures,
> but make sure you don't call pfFlatten above the transformation.
>

The MultiGen loader calls pfFlatten by default so you have to disable it:

        LoadFltMode(PFFLT_FLATTEN, FALSE);
  
> > 2). How does one 'get a handle' on Multigen models when
> > they are loaded. What I want to do (and yes I am aware of

> been posted. There is also the registerNode callback mechanisms
> provided with the multigen loader, but I've never tried this.

It worked quite well for me but I had to disable the PFFLT_FLATTEN and PFFLT_CLEAN
modes of the loader. Otherwise you are not sure if the names (and maybe other
attributes) you give to your models in the modeller will survive the loader(MultiGen 14.1).

Markus Nikolopoulos
Ericsson InfoCom AB
Box 1038
S-65115 KARLSTAD
SWEDEN

Tel. +46 (0)54 294832
Fax. +46 (0)54 294001
e-mail:mani++at++einku.ericsson.se


New Message Reply Date view Thread view Subject view Author view