Re: ptu on IRIX5.3

New Message Reply Date view Thread view Subject view Author view

Allan Schaffer (aschaffe)
Wed, 26 Apr 1995 23:19:02 -0700


On Apr 21, 5:01pm, Masahiko Yamanaka wrote:
> I'm using LoadPtu().
> It's nice on the Indigo/R4000-Entry(IRIX5.2),
> but seems not to work on Onyx-RE2(IRIX5.3).
> I re-compiled on Onyx.
>
> (dbx) run wry64.ptu
> Process 8327 (perfly.OPT) stopped on signal SIGSEGV: Segmentation
> violation (default) [_usgetinfo:243 ,0xfb006d4]
> Source (of usconfig.c) not available for Process 8327
> (dbx) where
> 0 _usgetinfo()
> 1 ilAuxBuffer::init(void)
>
> Does anyone know what was wrong ?

I had some reports of this very same problem of PTU crashing deep
within the IL, perhaps 6 months ago, but they disappeared
mysteriously and I was never able to determine what had caused them.

My assumption is that it is caused by a versions problem. Questions
to ask would be, what version of the ImageVision library are you
running, are you sure that it is the correct and most up-to-date
version for 5.3, and are you certain that the installation went
smoothly?

At one point I was able to reproduce the problem, but then I reloaded
the OS on the machine (a disk crashed, as I recall) and never saw the
problem again.

Allan

-- 
Allan Schaffer                                              aschaffe++at++sgi.com
Silicon Graphics                   http://reality.sgi.com/employees/aschaffe

New Message Reply Date view Thread view Subject view Author view

This archive was generated by hypermail 2.0b2 on Mon Aug 10 1998 - 17:51:26 PDT