Re: multiple pfChannels vs. multiple pfPipes

New Message Reply Date view Thread view Subject view Author view

Aaron Hightower (aaron++at++qbert.dseg.ti.com)
Thu, 16 Jun 1994 15:30:21 -0500 (CDT)


  A pfPipe is tied to a specific hardware pipeline according to the
  hardware screen that the graphics window is opened on. In initFunc,
  scrnselect should be used to select a hardware pipeline. If initFunc is
  NULL, the full-screen window will be opened on the hardware pipeline
  whose id corresponds to the pfPipe id, e.g.- scrnselect(1); will be used
  for pfPipe number 1. For best performance only one pfPipe should render
                            ^^^^^^^^^^^^^^^^
  to a given hardware pipeline. If multiple views on a single screen are
  desired, use multiple pfChannels.

> Also, if I get a second RE2 pipeline then obviously I would want multiple
> pfPipes, but assuming I still need more pfChannels than I have hardware
> pipelines, then I would assume the same partitioning issue applies. (That is,
> do I create 2 pfPipes -- one for each RE2 pipeline -- and split up the
> pfChannels among them or do I create multiple pfPipes per hardware pipeline and
> reduce the number of pfChannels per software pipe (i.e. pfPipes)?)

Hope this helps,
         _ _
| | *-------------------------------------------* | |
      __| |___ | Aaron.Hightower++at++dseg.ti.com 214.575.6759 | __| |___
      \ / | Simulation & Planning Technology | \ /
       \_ / | 6620 Chase Oaks Blvd M/S 8518 | \_ /
         \ ( | Plano TX 75023 | \ (
          \/ *-------------------------------------------* \/


New Message Reply Date view Thread view Subject view Author view

This archive was generated by hypermail 2.0b2 on Mon Aug 10 1998 - 17:50:20 PDT