Re: No Genlock Warning

New Message Reply Date view Thread view Subject view Author view

From: Luis Ignacio Miranda (lmiranda++at++sgi.com)
Date: 04/02/2001 08:09:03


Lee,

You can always avoid the message from Performer by using the PFNFYLEVEL environment
variable set to PFNFY_FATAL (see pfNotify() man page for details).

Anyway, depending on your application, it may be a good idea to genlock the pipes.

Hope this somehow helps

Nacho

Lee Marden wrote:

> Tze Lin,
>
> I'm having graphics stress related issues with my application on this
> 3 pipe (6 channel) system. My understanding is that if the
> pipes/channels are not synchronized correctly, then delays can be
> introduced in the rendering process. Since both perfly and my app issue
> this "No Genlock" warning, I thought that maybe my throughput issues
> might be related. I know my application is not setup, nor designed for,
> gangdraw. I've been told that I don't need gangdraw to optimally render
> on this hardware. However, I would like to get rid of this warning if
> possible. So... I'd like to know if the "No Genlock" message is truly
> genlock (i.e. video display) related, or if it's something more
> substantial, and the graphics pipes are out of alignment, and it's
> effecting my performance (cull/draw times, etc.).
>
> Thanks for your help,
> Lee
>
> Ong Tze Lin wrote:
> >
> > Hi Lee,
> >
> > Yup, Genlock locks the pipe to ensure they all
> > generate video frames at the same time. Yes, this can
> > also be used to ensure sync with the display device.
> >
> > Gangdraw OTOH makes sure they all swap buffers at
> > exactly the same time. This feature requires
> > you to cable up the Swap Ready ports on your
> > graphics hardware.
> >
> > So- for a fully synchronised hardware setup, you'd
> > connect up both genlock and swap ready.
> >
> > I'm not sure where exactly this check is performed,
> > although its bound to be at a very low level.
> >
> > Is there any particular reason you're looking for
> > this message? If you're looking just to disable it,
> > then use PFNFYLEVEL.. it will always appear when
> > multiple unsynchronized pipes are detected...
> >
> > Cheers,
> > Tze Lin
> >
> > --
> > Ong Tze Lin Tel/VNET: +65 771 0219
> > Principal Consultant Mobile : +65 9832 7125
> > SGI Asia Pacific Fax : +65 779 3650
> > 89 Science Park Dr, #03-03/05, Singapore 118261
> >
> > On Thu, 29 Mar 2001, Lee Marden wrote:
> >
> > > Thanks. When you mean hardware genlock between the pipes, are talking
> > > gangdraw between the pipes? My understanding is that gangdraw is
> > > responsible for synching between pipes, while genlock is for synching to
> > > an external video, such as the projectors. I believe this message is
> > > coming from Performer, but I don't know what sub-system, or library.
> > > Would you know the name of the part of Performer that's checking for
> > > this?
> > >
> > > Thanks,
> > > Lee
> > >
> > > Ong Tze Lin wrote:
> > > >
> > > > Hi Lee,
> > > >
> > > > Just means you don't have hardware genlock between
> > > > your pipes. Your channels are still sync'ed
> > > > internally, which may or may not be adequate for
> > > > your simulation needs.
> > > >
> > > > Cheers,
> > > > Tze Lin
> > > >
> > > > --
> > > > Ong Tze Lin Tel/VNET: +65 771 0219
> > > > Principal Consultant Mobile : +65 9832 7125
> > > > SGI Asia Pacific Fax : +65 779 3650
> > > > 89 Science Park Dr, #03-03/05, Singapore 118261
> > > >
> > > > On Wed, 28 Mar 2001, Lee Marden wrote:
> > > >
> > > > > pfUsers,
> > > > >
> > > > > I'm getting a warning when I run perfly, that indicates that there is
> > > > > a problem with genlock across my three pipes. I use the following to
> > > > > setup the three MCOs (2 channels each):
> > > > >
> > > > > ---
> > > > > set DISPLAY=:0.0
> > > > > /usr/gfx/setmon -x -S -p 0 2++at++1025x768_60
> > > > > set DISPLAY=:0.1
> > > > > /usr/gfx/setmon -g -x -S -p 1 2++at++1025x768_60
> > > > > set DISPLAY=:0.2
> > > > > /usr/gfx/setmon -g -x -S -p 2 2++at++1025x768_60
> > > > >
> > > > > /usr/gfx/stopgfx; /usr/gfx/startgfx &
> > > > > ---
> > > > >
> > > > > The scene looks ok, so I know that the MCOs are working, but I get the
> > > > > following warnings:
> > > > > 17724 PF Warning/Resource: !!!!!!!!!!!!!!!!!! NO GENLOCK
> > > > > !!!!!!!!!!!!!!!!!!!!!!
> > > > > 17724 PF Warning/Resource: Screen 1 is phase-shifted 68.657346
> > > > > degrees from master screen 0.
> > > > > 17724 PF Warning/Resource: !!!!!!!!!!!!!!!!!! NO GENLOCK
> > > > > !!!!!!!!!!!!!!!!!!!!!!
> > > > > 17724 PF Warning/Resource: !!!!!!!!!!!!!!!!!! NO GENLOCK
> > > > > !!!!!!!!!!!!!!!!!!!!!!
> > > > > 17724 PF Warning/Resource: Screen 2 is phase-shifted 78.312222
> > > > > degrees from master screen 0.
> > > > > 17724 PF Warning/Resource: !!!!!!!!!!!!!!!!!! NO GENLOCK
> > > > > !!!!!!!!!!!!!!!!!!!!!!
> > > > >
> > > > > I've looked through the perfly code and can't find this message. Is
> > > > > this a Performer message? Any ideas what might be causing this? Should
> > > > > I be concerned?
> > > > >
> > > > > Thanks,
> > > > > Lee
> > > > > --
> > > > > ------------------------------------------------------------------------
> > > > > Lee Marden Raytheon Company
> > > > > Principal Software Engineer Northeast C3I Systems
> > > > > Advanced Modeling & Simulation 50 Apple Hill Dr. (T3MJ21)
> > > > > Technology Section Tewksbury, MA 01876
> > > > > Phone: (978) 858-9487 Fax: (978) 858-4336
> > > > > Email:lee_marden++at++raytheon.com Intranet: http://amasts.msd.ray.com/~lms
> > > > > ------------------------------------------------------------------------
> > > > > -----------------------------------------------------------------------
> > > > > List Archives, FAQ, FTP: http://www.sgi.com/software/performer/
> > > > > Open Development Project: http://oss.sgi.com/projects/performer/
> > > > > Submissions: info-performer++at++sgi.com
> > > > > Admin. requests: info-performer-request++at++sgi.com
> > > > >
> > >
> > > --
> > > ------------------------------------------------------------------------
> > > Lee Marden Raytheon Company
> > > Principal Software Engineer Northeast C3I Systems
> > > Advanced Modeling & Simulation 50 Apple Hill Dr. (T3MJ21)
> > > Technology Section Tewksbury, MA 01876
> > > Phone: (978) 858-9487 Fax: (978) 858-4336
> > > Email:lee_marden++at++raytheon.com Intranet: http://amasts.msd.ray.com/~lms
> > > ------------------------------------------------------------------------
> > >
> >
> > -----------------------------------------------------------------------
> > List Archives, FAQ, FTP: http://www.sgi.com/software/performer/
> > Open Development Project: http://oss.sgi.com/projects/performer/
> > Submissions: info-performer++at++sgi.com
> > Admin. requests: info-performer-request++at++sgi.com
>
> --
> ------------------------------------------------------------------------
> Lee Marden Raytheon Company
> Principal Software Engineer Northeast C3I Systems
> Advanced Modeling & Simulation 50 Apple Hill Dr. (T3MJ21)
> Technology Section Tewksbury, MA 01876
> Phone: (978) 858-9487 Fax: (978) 858-4336
> Email:lee_marden++at++raytheon.com Intranet: http://amasts.msd.ray.com/~lms
> ------------------------------------------------------------------------
> -----------------------------------------------------------------------
> List Archives, FAQ, FTP: http://www.sgi.com/software/performer/
> Open Development Project: http://oss.sgi.com/projects/performer/
> Submissions: info-performer++at++sgi.com
> Admin. requests: info-performer-request++at++sgi.com

--
NB:  INFORMATION IN THIS MESSAGE IS SGI CONFIDENTIAL.  IT IS INTENDED SOLELY
FOR THE PERSON(S) TO WHOM IT IS ADDRESSED AND MAY NOT BE COPIED, USED,
DISCLOSED OR DISTRIBUTED TO OTHERS WITHOUT SGI CONSENT.  IF YOU ARE NOT
THE INTENDED RECIPIENT PLEASE WILL YOU NOTIFY ME BY EMAIL OR TELEPHONE,
DELETE THE MESSAGE FROM YOUR SYSTEM IMMEDIATELY AND DESTROY ANY PRINTED
COPIES.