From: c937161++at++student.dtu.dk
Date: 08/14/2000 00:58:42
Hi
One way to solve this is by using a message queue between the two systems.
The math model then provides data (motion or whatever) asynchronously, and
the visual system should be able to interpolate the data (or extrapolate
when data is late). This is how I do it anyway.
Regards,
Hans
On Sun, 13 Aug 2000, Michal Cilek wrote:
> Hello, we are having a trouble in synchronizing two machines, Origin as
> mathematical model computer and Onyx as Visualization computer.
>
> The pfSyncFrame, pfFrame calls are making big role in this, please can
> you send me links to manuals and related solutions?
>
> The issue is that the Origin data rate is 66.6666 Hz and the Onyx could
> be programmed only to whole number frequencies (like 67).
>
> Please help, this is urgent. Any suggestions welcomed.
>
> Michal Cilek
>
-- Hans Palbøl
This archive was generated by hypermail 2b29 : Mon Aug 14 2000 - 00:59:53 PDT