The FC and Suse startup scripts use ethtool to check for link present. This has
problems on my laptop with Broadcom because it quieries settings before
bringing link up. The problem is driver returns EAGAIN when queried for
settings but not up. Just go ahead and return values anyway, the supported and
link
state values will be correct, speed will end up being 10BaseT/Half which is a
reasonable default.
Signed-off-by: Stephen Hemminger <shemminger@xxxxxxxx>
diff -Nru a/drivers/net/b44.c b/drivers/net/b44.c
--- a/drivers/net/b44.c 2004-11-29 09:41:27 -08:00
+++ b/drivers/net/b44.c 2004-11-29 09:41:27 -08:00
@@ -1487,8 +1487,6 @@
{
struct b44 *bp = netdev_priv(dev);
- if (!(bp->flags & B44_FLAG_INIT_COMPLETE))
- return -EAGAIN;
cmd->supported = (SUPPORTED_Autoneg);
cmd->supported |= (SUPPORTED_100baseT_Half |
SUPPORTED_100baseT_Full |
|